Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Computation of mean cerebral blood flow velocity for the assessment of cerebral autoregulation: Comparison of different strategies

Articolo
Data di Pubblicazione:
2019
Citazione:
Computation of mean cerebral blood flow velocity for the assessment of cerebral autoregulation: Comparison of different strategies / E. Vaini, V. Bari, D. Tonon, B. Cairo, B. De Maria, L. Faes, G. Rossato, A. Porta. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-887X. - 46:(2019). ((Intervento presentato al convegno CinC Computing in Cardiology 2019 8th 11 September tenutosi a Singapore nel 2019 [10.23919/CinC49843.2019.9005741].
Abstract:
Cerebral autoregulation (CA) is a complex mechanism stabilizing cerebral blood flow (CBF) against arterial pressure (AP) changes. CBF is commonly surrogated with the CBF velocity (CBFV) recorded via transcranial Doppler device from the middle cerebral artery. Most of the studies evaluating CA compute mean CBFV (MCBFV) on a beat-to-beat basis along with mean AP (MAP), but there is not a standard approach to derive MCBFV. In this study, we compare three different strategies to calculate MCBFV: i) between two consecutive diastolic points detected on the CBFV signal (MCBFVCBFV); ii) between two consecutive diastolic points detected on the AP signal (MCBFVAP); iii) between two consecutive R-wave peaks detected on the ECG (MCBFVECG). We analyzed ECG, noninvasive AP and CBFV signals recorded from 23 subjects (age: 28 ± 9 yrs, 13 female) at rest in supine position (REST) and during head-up tilt at 60° (TILT). While means were similar regardless of the considered strategy, variances significantly varied with MCBFVCBFV and MCBFVECG strategy producing the largest and the smallest variance respectively. This result stresses the need to standardize the approach for MCBFV computation to reduce the variability of the results solely due to the method adopted for its computation and favor clinical applications of CA assessment.
Tipologia IRIS:
01 - Articolo su periodico
Elenco autori:
E. Vaini, V. Bari, D. Tonon, B. Cairo, B. De Maria, L. Faes, G. Rossato, A. Porta
Autori di Ateneo:
BARI VLASTA ( autore )
CAIRO BEATRICE ( autore )
PORTA ALBERTO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/735886
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0