Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • People
  • Projects
  • Fields
  • Units
  • Outputs
  • Third Mission

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • People
  • Projects
  • Fields
  • Units
  • Outputs
  • Third Mission
  1. Outputs

Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

Academic Article
Publication Date:
2016
Citation:
Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation / C. Sergio, M. Massimo, F. Gaetano, F. Tundo, R. Stefania, D.R. Antonio, C. Michela, B. Majocchi, M. Vittoria, D.I. Pasquale, C. Valentina, P. Salvatore, C. Tondo. - In: CARDIOLOGY RESEARCH AND PRACTICE. - ISSN 2090-8016. - 2016:(2016), pp. 5106127.1-5106127.5. [10.1155/2016/5106127]
abstract:
INTRODUCTION:
Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up.
METHODS:
A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years.
RESULTS:
There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; p = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102 ± 24.8 min, resp.; p = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p = 0.61 and 0.57). There were no significant differences in procedural-related complications.
CONCLUSION:
The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter.
IRIS type:
01 - Articolo su periodico
Keywords:
Cardiology and Cardiovascular Medicine
List of contributors:
C. Sergio, M. Massimo, F. Gaetano, F. Tundo, R. Stefania, D.R. Antonio, C. Michela, B. Majocchi, M. Vittoria, D.I. Pasquale, C. Valentina, P. Salvatore, C. Tondo
Authors of the University:
TONDO CLAUDIO ( author )
Link to information sheet:
https://air.unimi.it/handle/2434/534506
Full Text:
https://air.unimi.it/retrieve/handle/2434/534506/934120/5106127.pdf
  • Research Areas

Research Areas

Concepts


Settore MED/11 - Malattie dell'Apparato Cardiovascolare
  • Guide
  • Help
  • Accessibility
  • Privacy
  • Use of cookies
  • Legal notices

Powered by VIVO | Designed by Cineca | 26.7.0.0