Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

Articolo
Data di Pubblicazione:
2016
Citazione:
Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation / C. Sergio, M. Massimo, F. Gaetano, F. Tundo, R. Stefania, D.R. Antonio, C. Michela, B. Majocchi, M. Vittoria, D.I. Pasquale, C. Valentina, P. Salvatore, C. Tondo. - In: CARDIOLOGY RESEARCH AND PRACTICE. - ISSN 2090-8016. - 2016:(2016), pp. 5106127.1-5106127.5. [10.1155/2016/5106127]
Abstract:
INTRODUCTION: Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. METHODS: A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. RESULTS: There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; p = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102 ± 24.8 min, resp.; p = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p = 0.61 and 0.57). There were no significant differences in procedural-related complications. CONCLUSION: The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Cardiology and Cardiovascular Medicine
Elenco autori:
C. Sergio, M. Massimo, F. Gaetano, F. Tundo, R. Stefania, D.R. Antonio, C. Michela, B. Majocchi, M. Vittoria, D.I. Pasquale, C. Valentina, P. Salvatore, C. Tondo
Autori di Ateneo:
TONDO CLAUDIO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/534506
Link al Full Text:
https://air.unimi.it/retrieve/handle/2434/534506/934120/5106127.pdf
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/11 - Malattie dell'Apparato Cardiovascolare
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0