Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Mechanical power during robotic-assisted laparoscopic prostatectomy: an observational study

Articolo
Data di Pubblicazione:
2024
Citazione:
Mechanical power during robotic-assisted laparoscopic prostatectomy: an observational study / T. Pozzi, S. Coppola, G. Catozzi, A. Colombo, M. Chioccola, E. Duscio, F. Di Marco, D. Chiumello. - In: JOURNAL OF CLINICAL MONITORING AND COMPUTING. - ISSN 1573-2614. - (2024), pp. 1-9. [10.1007/s10877-024-01170-1]
Abstract:
Background: Robotic-assisted laparoscopic radical prostatectomy (RALP) requires pneumoperitoneum and steep Trendelenburg position. Our aim was to investigate the influence of the combination of pneumoperitoneum and Trendelenburg position on mechanical power and its components during RALP. Methods: Sixty-one prospectively enrolled patients scheduled for RALP were studied in supine position before surgery, during pneumoperitoneum and Trendelenburg position and in supine position after surgery at constant ventilatory setting. In a subgroup of 17 patients the response to increasing positive end-expiratory pressure (PEEP) from 5 to 10 cmH2O was studied. Results: The application of pneumoperitoneum and Trendelenburg position increased the total mechanical power (13.8 [11.6 - 15.5] vs 9.2 [7.5 - 11.7] J/min, p < 0.001) and its elastic and resistive components compared to supine position before surgery. In supine position after surgery the total mechanical power and its elastic component decreased but remained higher compared to supine position before surgery. Increasing PEEP from 5 to 10 cmH2O within each timepoint significantly increased the total mechanical power (supine position before surgery: 9.8 [8.4 - 10.4] vs 12.1 [11.4 - 14.2] J/min, p < 0.001; pneumoperitoneum and Trendelenburg position: 13.8 [12.2 - 14.3] vs 15.5 [15.0 - 16.7] J/min, p < 0.001; supine position after surgery: 10.2 [9.4 - 10.7] vs 12.7 [12.0 - 13.6] J/min, p < 0.001), without affecting respiratory system elastance. Conclusion: Mechanical power in healthy patients undergoing RALP significantly increased both during the pneumoperitoneum and Trendelenburg position and in supine position after surgery. PEEP always increased mechanical power without ameliorating the respiratory system elastance.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Intraoperative mechanical ventilation; Mechanical Power; Robotic Surgery
Elenco autori:
T. Pozzi, S. Coppola, G. Catozzi, A. Colombo, M. Chioccola, E. Duscio, F. Di Marco, D. Chiumello
Autori di Ateneo:
CHIUMELLO DAVIDE ALBERTO ( autore )
COPPOLA SILVIA ( autore )
DI MARCO FABIANO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/1084608
Link al Full Text:
https://air.unimi.it/retrieve/handle/2434/1084608/2498313/s10877-024-01170-1.pdf
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/41 - Anestesiologia
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.5.2.0