Reliability of the North Star Ambulatory Assessment in a multicentric setting.

Articolo
Data di Pubblicazione:
2009
Citazione:
Reliability of the North Star Ambulatory Assessment in a multicentric setting. / E.S. Mazzone, S. Messina, G. Vasco, M. Main, M. Eagle, A. D'Amico, L. Doglio, L. Politano, F. Cavallaro, S. Frosini, L. Bello, F. Magri, A. Corlatti, E. Zucchini, B. Brancalion, F. Rossi, M. Ferretti, MG Motta, MR Cecio, A. Berardinelli, P. Alfieri, T. Mongini, A. Pini, G. Astrea, R. Battini, G. Comi, E. Pegoraro, L. Morandi, M. Pane, C. Angelini, C. Bruno, M. Villanova, G. Vita, M.A. Donati, E. Bertini, E. Mercuri. - In: NEUROMUSCULAR DISORDERS. - ISSN 0960-8966. - 19:7(2009 Jul), pp. 458-461.
Abstract:
The aim of this study was to investigate the suitability of the North Star Ambulatory Assessment as a possible outcome measure in multicentric clinical trials. More specifically we wished to investigate the level of training needed for achieving a good interobserver reliability in a multicentric setting. The scale was specifically designed for ambulant children with Duchenne Muscular Dystrophy and includes 17 items that are relevant for this cohort. Thirteen Italian centers participated in the study. In the first phase of the study we provided two training videos and an example of the scale performed on a child. After the first session of training, all the 13 examiners were asked to send a video with an assessment performed in their centre and to score all the videos collected. There were no difficulties in performing the items and in obtaining adequate videos with a hand held camera but the results showed a poor interobserver reliability (<.5). After a second training session with review and discussion of the videos previously scored, the same examiners were asked to score three new videos. The results of this session had an excellent interobserver reliability (.995). The level of agreement was maintained even when the same videos were rescored after a month, showing a significant intra-observer reliability (.95). Our results suggest that the NSAA is a test that can be easily performed, completed in 10 min and can be used in a multicentric setting, providing that adequate training is administered.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Duchenne Muscular Dystrophy; Function; Outcome
Elenco autori:
E.S. Mazzone, S. Messina, G. Vasco, M. Main, M. Eagle, A. D'Amico, L. Doglio, L. Politano, F. Cavallaro, S. Frosini, L. Bello, F. Magri, A. Corlatti, E. Zucchini, B. Brancalion, F. Rossi, M. Ferretti, MG Motta, MR Cecio, A. Berardinelli, P. Alfieri, T. Mongini, A. Pini, G. Astrea, R. Battini, G. Comi, E. Pegoraro, L. Morandi, M. Pane, C. Angelini, C. Bruno, M. Villanova, G. Vita, M.A. Donati, E. Bertini, E. Mercuri
Autori di Ateneo:
COMI GIACOMO PIETRO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/72156
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/26 - Neurologia
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0