Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Comprehensive effects of left ventricular assist device speed changes on alveolar gas exchange, sleep ventilatory pattern, and exercise performance

Articolo
Data di Pubblicazione:
2018
Citazione:
Comprehensive effects of left ventricular assist device speed changes on alveolar gas exchange, sleep ventilatory pattern, and exercise performance / A. Apostolo, S. Paolillo, M. Contini, C. Vignati, V. Tarzia, J. Campodonico, M. Mapelli, M. Massetti, J. Bejko, F. Righini, T. Bottio, N. Bonini, E. Salvioni, P. Gugliandolo, G. Parati, C. Lombardi, G. Gerosa, L. Salvi, F. Alamanni, P. Agostoni. - In: THE JOURNAL OF HEART AND LUNG TRANSPLANTATION. - ISSN 1053-2498. - (2018 Sep). [10.1016/j.healun.2018.07.005]
Abstract:
BACKGROUND: Increasing left ventricular assist device (LVAD) pump speed according to the patient's activity is a fascinating hypothesis. This study analyzed the short-term effects of LVAD speed increase on cardiopulmonary exercise test (CPET) performance, muscle oxygenation (near-infrared spectroscopy), diffusion capacity of the lung for carbon monoxide (DLCO) and nitric oxide (DLNO), and sleep quality. METHODS: We analyzed CPET, DLCO and DLNO, and sleep in 33 patients supported with the Jarvik 2000 (Jarvik Heart Inc., New York, NY). After a maximal CPET (n = 28), patients underwent 2 maximal CPETs with LVAD speed randomly set at 3 or increased from 3 to 5 during effort (n = 15). Then, at LVAD speed randomly set at 2 or 4, we performed (1) constant workload CPETs assessing O2 kinetics, cardiac output (CO), and muscle oxygenation (n = 15); (2) resting DLCO and DLNO (n = 18); and (3) nocturnal cardiorespiratory monitoring (n = 29). RESULTS: The progressive pump speed increase raised peak volume of oxygen consumption (12.5 ± 2.5 ml/min/kg vs 11.7 ± 2.8 ml/min/kg at speed 3; p = 0.001). During constant workload, from speed 2 to 4, CO increased (at rest: 3.18 ± 0.76 liters/min vs 3.69 ± 0.75 liters/min, p = 0.015; during exercise: 5.91 ± 1.31 liters/min vs 6.69 ± 0.99 liters/min, p = 0.014), and system efficiency (τ = 65.8 ± 15.1 seconds vs 49.9 ± 14.8 seconds, p = 0.002) and muscle oxygenation improved. At speed 4, DLCO decreased, and obstructive apneas increased despite a significant apnea/hypopnea index and a reduction of central apneas. CONCLUSIONS: Short-term LVAD speed increase improves exercise performance, CO, O2 kinetics, and muscle oxygenation. However, it deteriorates lung diffusion and increases obstructive apneas, likely due to an increase of intrathoracic fluids. Self-adjusting LVAD speed is a fascinating but possibly unsafe option, probably requiring a monitoring of intrathoracic fluids.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
CPET; LVAD; cardiac output; exercise; lung diffusion; muscle oxygenation
Elenco autori:
A. Apostolo, S. Paolillo, M. Contini, C. Vignati, V. Tarzia, J. Campodonico, M. Mapelli, M. Massetti, J. Bejko, F. Righini, T. Bottio, N. Bonini, E. Salvioni, P. Gugliandolo, G. Parati, C. Lombardi, G. Gerosa, L. Salvi, F. Alamanni, P. Agostoni
Autori di Ateneo:
AGOSTONI PIERGIUSEPPE ( autore )
MAPELLI MASSIMO ( autore )
VIGNATI CARLO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/591736
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/11 - Malattie dell'Apparato Cardiovascolare
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0