Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm

Articolo
Data di Pubblicazione:
2015
Citazione:
Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm / A.D. Annoni, D. Andreini, G. Pontone, A. Formenti, M. Petullà, E. Consiglio, E. Nobili, A. Baggiano, E. Conte, S. Mushtaq, E. Bertella, F. Billi, A.L. Bartorelli, P. Montorsi, M. Pepi. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2404. - 16:12(2015), pp. 1366-1373.
Abstract:
Aims To evaluate the feasibility of ultra-low-dose CT for left atrium and pulmonary veins using new model-based iterative reconstruction (MBIR) algorithm. Methods and results Two hundred patients scheduled for catheter ablation were randomized into two groups: Group 1 (100 patients, Multidetector row CT (MDCT) with MBIR, no ECG triggering, tube voltage and tube current of 100 kV and 60 mA, respectively) and Group 2 [100 patients, MDCT with adaptive statistical iterative reconstruction algorithm (ASIR), no ECG triggering, and kV and mA tailored on patient BMI]. Image quality, CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of left atrium (LA) and pulmonary veins, and effective dose (ED) were evaluated for each exam and compared between two groups. No significant differences between groups in terms of population characteristics, cardiovascular risk factors, anatomical features, prevalence of persistent atrial fibrillation and image quality score. Statistically significant differences were found between Group 1 and Group 2 in mean attenuation, SNR, and CNR of LA. Significantly, lower values of noise were found in Group 1 versus Group 2. Group 1 showed a significantly lower mean ED in comparison with Group 2 (0.41±0.04 versus 4.17±2.7 mSv). Conclusion The CT for LA and pulmonary veins imaging using MBIR is feasible and allows examinations with very low-radiation exposure without loss of image quality.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Atrial fibrillation; Computed tomography imaging; Dose-reducing software; Left atrium; Algorithms; Atrial Fibrillation; Cardiac-Gated Imaging Techniques; Contrast Media; Feasibility Studies; Female; Heart Atria; Humans; Iopamidol; Male; Middle Aged; Pulmonary Veins; Radiographic Image Interpretation, Computer-Assisted; Signal-To-Noise Ratio; Software; Tomography, X-Ray Computed; Radiation Dosage; Radiology, Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
Elenco autori:
A.D. Annoni, D. Andreini, G. Pontone, A. Formenti, M. Petullà, E. Consiglio, E. Nobili, A. Baggiano, E. Conte, S. Mushtaq, E. Bertella, F. Billi, A.L. Bartorelli, P. Montorsi, M. Pepi
Autori di Ateneo:
ANDREINI DANIELE ( autore )
MONTORSI PIERO ( autore )
PONTONE GIANLUCA ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/478666
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/11 - Malattie dell'Apparato Cardiovascolare
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0