Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

FRETS-VWF73 rather than CBA assay reflects ADAMTS13 proteolytic activity in acquired thrombotic thrombocytopenic purpura patients

Articolo
Data di Pubblicazione:
2014
Citazione:
FRETS-VWF73 rather than CBA assay reflects ADAMTS13 proteolytic activity in acquired thrombotic thrombocytopenic purpura patients / I. Mancini, C. Valsecchi, L.A. Lotta, L. Deforche, S. Pontiggia, M. Bajetta, R. Palla, K. Vanhoorelbeke, F. Peyvandi. - In: THROMBOSIS AND HAEMOSTASIS. - ISSN 0340-6245. - 112:2(2014 Aug), pp. 297-303. [10.1160/TH13-08-0688]
Abstract:
Collagen-binding activity (CBA) and FRETS-VWF73 assays are widely adopted methods for the measurement of the plasmatic activity of ADAMTS13, the von Willebrand factor (VWF) cleaving-protease. Accurately assessing the severe deficiency of ADAMTS13 is important in the management of thrombotic thrombocytopenic purpura (TTP). However, non-concordant results between the two assays have been reported in a small but relevant percentage of TTP cases. We investigated whether CBA or FRETS-VWF73 assay reflects ADAMTS13 proteolytic activity in acquired TTP patients with non-concordant measurements. Twenty plasma samples with non-concordant ADAMTS13 activity results, <10% using FRETS-VWF73 and ≥20% using CBA, and 11 samples with concordant results, <10% using either FRETS-VWF73 and CBA assays, were analysed. FRETS-VWF73 was performed in the presence of 1.5 M urea. ADAMTS13 activities were also measured under flow conditions and the VWF multimer pat tern was defined in order to verify the presence of ultra-large VWF due to ADAMTS13 deficiency. In FRETS-VWF73 assay with 1.5 M urea, ADAMTS13 activity significantly increased in roughly 50% of the samples with non-concordant results, whereas it remained undetectable in all samples with concordant measurements. Under flow conditions, all tested samples showed reduced ADAMTS13 activity. Finally, samples with non-concordant results showed a ratio of high molecular weight VWF multimers higher than normal. Our results support the use of FRETS-VWF73 over CBA assay for the assessment of ADAMTS13 severe deficiency and indicate urea as one cause of the observed differences.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
ADAMTS13 activity assay; Autoantibodies; Flow assay; TTP; Von Willebrand factor; Hematology
Elenco autori:
I. Mancini, C. Valsecchi, L.A. Lotta, L. Deforche, S. Pontiggia, M. Bajetta, R. Palla, K. Vanhoorelbeke, F. Peyvandi
Autori di Ateneo:
PAYVANDI FLORA ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/253306
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/09 - Medicina Interna
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0