Retrospective radiation dosimetry using OSL of electronic components : results of an inter-laboratory comparison

Articolo
Data di Pubblicazione:
2014
Citazione:
Retrospective radiation dosimetry using OSL of electronic components : results of an inter-laboratory comparison / C. Bassinet, C. Woda, E. Bortolin, S. Della Monaca, P. Fattibene, M.C. Quattrini, B. Bulanek, D. Ekendahl, C.I. Burbidge, V. Cauwels, E. Kouroukla, T. Geber-Bergstrand, A. Mrozik, B. Marczewska, P. Bilski, S. Sholom, S.W.S. McKeever, R.W. Smith, I. Veronese, A. Galli, L. Panzeri, M. Martini. - In: RADIATION MEASUREMENTS. - ISSN 1350-4487. - 71(2014), pp. 475-479. ((Intervento presentato al 17. convegno Conference on Solid State Dosimetry (SSD) tenutosi a Recife nel 2013.
Abstract:
In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Emergency dosimeter; Mobile phones; OSL; Radiological accident; Resistor; Retrospective dosimetry; Radiation; Instrumentation
Elenco autori:
C. Bassinet, C. Woda, E. Bortolin, S. Della Monaca, P. Fattibene, M.C. Quattrini, B. Bulanek, D. Ekendahl, C.I. Burbidge, V. Cauwels, E. Kouroukla, T. Geber-Bergstrand, A. Mrozik, B. Marczewska, P. Bilski, S. Sholom, S.W.S. McKeever, R.W. Smith, I. Veronese, A. Galli, L. Panzeri, M. Martini
Autori di Ateneo:
VERONESE IVAN ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/250775
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0