Data di Pubblicazione:
2013
Citazione:
Performances of a 1″×1″ Cs2LiYCl6 scintillator detector / L. Pellegri, E. Bizzarri, N. Blasi, F. Camera, A. Giaz, R. Avigo, C. Boiano, S. Brambilla, S. Ceruti, B. Million, S. Riboldi, O. Wieland - In: IEEE Nuclear Science Symposium Conference Record[s.l] : Institute of Electrical and Electronics Engineers Inc., 2013. - ISBN 9781479905348. - pp. 1-3 (( convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul, kor nel 2013 [10.1109/NSSMIC.2013.6829614].
Abstract:
In this work we have measured the performances of a 1″×1″ sample of a CLYC scintillator (Cs2LiYCl6) with 95% enrichment of 6Li produced by RMD. Different PMT models, with borosilicate glass window or quartz window have been used. The Pulse line-shape and Pulse shape discrimination for different type of incident radiation (gamma-rays and thermal neutrons) have been investigated. The response to thermal neutrons has been measured using an AmBe source and a digital oscilloscope. A measurement of the internal radiation and the energy resolution for different gamma rays have been additionally performed.
Tipologia IRIS:
03 - Contributo in volume
Keywords:
elpasolites; gamma-ray detectors; neutron detectors; pulse shape discrimination; radiation detectors; scintillators; Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
Elenco autori:
L. Pellegri, E. Bizzarri, N. Blasi, F. Camera, A. Giaz, R. Avigo, C. Boiano, S. Brambilla, S. Ceruti, B. Million, S. Riboldi, O. Wieland
Link alla scheda completa:
Titolo del libro:
IEEE Nuclear Science Symposium Conference Record