PERFORMANCE OF A LARGE-SCALE PROTOTYPE OF THE ATLAS ACCORDION ELECTROMAGNETIC CALORIMETER / D. GINGRICH, G. GREENIAUS, P. KITCHING, B. OLSEN, J. PINFOLD, N. RODNING, E. BOOS, B. ZHAUTYKOV, B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. BONIFACE, J. COLAS, S. JEZEQUEL, T. LEFLOUR, M. MAIRE, F. RIVAL, M. STIPCEVIC, J. THION, D. VANDENPLAS, I. WINGERTERSEEZ, R. ZITOUN, Y. ZOLNIEROWSKI, M. CHMEISSANI, E. FERNANDEZ, L. GARRIDO, M. MARTINEZ, C. PADILLA, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, L. BAISIN, J. BERSET, J. CHEVALLEY, F. GIANOTTI, O. GILDEMEISTER, C. MARIN, M. NESSI, L. POGGIOLI, W. RICHTER, V. VUILLEMIN, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. SCHWINDLING, J. TEIGER, J. COLLOT, P. DESAINTIGNON, D. DZAHINI, J. HOSTACHY, G. LABORIE, G. MAHOUT, E. MERCHEZ, J. POUXE, L. HERVAS, A. CHEKHTMAN, M. COUSINOU, P. DARGENT, B. DINKESPILLER, F. ETIENNE, P. FASSNACHT, D. FOUCHEZ, L. MARTIN, A. MIOTTO, E. MONNIER, E. NAGY, C. OLIVETTO, S. TISSERANT, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, L. COZZI, A. CRAVERO, N. FEDYAKIN, A. FERRARI, L. MANDELLI, M. MAZZANTI, L. PERINI, P. SALA, G. AZUELOS, G. BEAUDOIN, P. DEPOMMIER, E. LEONFLORIAN, C. LEROY, P. ROY, M. SEMAN, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, D. FOURNIER, A. HRISOHO, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, A. SCHAFFER, N. SEGUINMOREAU, L. SERIN, V. TISSERAND, I. VICHOU, B. CANTON, J. DAVID, J. GENAT, D. IMBAULT, O. LEDORTZ, A. SAVOYNAVARRO, P. SCHWEMLING, L. EEK, B. LUNDJENSEN, J. SODERQVIST, M. LEFEBVRE, S. ROBERTSON, J. WHITE. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 364:2(1995), pp. 290-306. [10.1016/0168-9002(95)00406-8]
Abstract:
A 2 m long prototype of a lead-liquid argon electromagnetic calorimeter with accordion-shaped electrodes, conceived as a sector of the barrel calorimeter of the future ATLAS experiment at the LHC, has been tested with electron and pion beams in the energy range 10 to 287 GeV. A sampling term of 10%/root E(GeV) was obtained for electrons in the rapidity range 0 < eta < 1, while the constant term measured over an area of about 1 m(2) is 0.69%. With a cell size of 2.7 cm the position resolution is. about 4 mm/root E(GeV).
Tipologia IRIS:
01 - Articolo su periodico
Elenco autori:
D. Gingrich, G. Greeniaus, P. Kitching, B. Olsen, J. Pinfold, N. Rodning, E. Boos, B. Zhautykov, B. Aubert, A. Bazan, B. Beaugiraud, J. Boniface, J. Colas, S. Jezequel, T. Leflour, M. Maire, F. Rival, M. Stipcevic, J. Thion, D. Vandenplas, I. Wingerterseez, R. Zitoun, Y. Zolnierowski, M. Chmeissani, E. Fernandez, L. Garrido, M. Martinez, C. Padilla, H. Gordon, V. Radeka, D. Rahm, D. Stephani, L. Baisin, J. Berset, J. Chevalley, F. Gianotti, O. Gildemeister, C. Marin, M. Nessi, L. Poggioli, W. Richter, V. Vuillemin, J. Baze, L. Gosset, P. Lavocat, J. Lottin, B. Mansoulie, J. Meyer, J. Renardy, J. Schwindling, J. Teiger, J. Collot, P. Desaintignon, D. Dzahini, J. Hostachy, G. Laborie, G. Mahout, E. Merchez, J. Pouxe, L. Hervas, A. Chekhtman, M. Cousinou, P. Dargent, B. Dinkespiller, F. Etienne, P. Fassnacht, D. Fouchez, L. Martin, A. Miotto, E. Monnier, E. Nagy, C. Olivetto, S. Tisserant, G. Battistoni, D. Camin, D. Cavalli, G. Costa, L. Cozzi, A. Cravero, N. Fedyakin, A. Ferrari, L. Mandelli, M. Mazzanti, L. Perini, P. Sala, G. Azuelos, G. Beaudoin, P. Depommier, E. Leonflorian, C. Leroy, P. Roy, M. Seman, E. Auge, R. Chase, J. Chollet, C. Delataille, L. Fayard, D. Fournier, A. Hrisoho, B. Merkel, J. Noppe, G. Parrour, P. Petroff, A. Schaffer, N. Seguinmoreau, L. Serin, V. Tisserand, I. Vichou, B. Canton, J. David, J. Genat, D. Imbault, O. Ledortz, A. Savoynavarro, P. Schwemling, L. Eek, B. Lundjensen, J. Soderqvist, M. Lefebvre, S. Robertson, J. White
Link alla scheda completa: