LC-ESI-MS/MS determination of 4-hydroxy-trans-2-nonenal Michael adducts with cysteine and histidine-containing peptides as early markers of oxidative stress in excitable tissues
Articolo
Data di Pubblicazione:
2005
Citazione:
LC-ESI-MS/MS determination of 4-hydroxy-trans-2-nonenal Michael adducts with cysteine and histidine-containing peptides as early markers of oxidative stress in excitable tissues / M. Orioli, G. Aldini, G. Beretta, R. Maffei Facino, M. Carini. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 827:1(2005), pp. 109-118. [10.1016/j.jchromb.2005.04.025]
Abstract:
A sensitive, selective, specific and rapid liquid chromatographic-electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous determination in skeletal muscle of the Michael adducts between 4-hydroxy-trans-2-nonenal (HNE), one of the most reactive lipid peroxidation-driven unsaturated aldehyde, and glutathione (GSH) and the endogenous histidine-containing dipeptides carnosine (CAR) and anserine (ANS), with the final aim to use conjugated adducts as specific and unequivocal markers of lipid peroxidation. Samples (skeletal muscle homogenates from male rats) were prepared by protein precipitation with 1 vol. of a HClO(4) solution (4.2%; w/v) containing H-Tyr-His-OH as internal standard. The supernatant, diluted (1:1, v/v) in mobile phase, was separated on a Phenomenex Sinergy polar-RP column with a mobile phase of water-acetonitrile-heptafluorobutyric acid (9:1:0.01, v/v/v) at a flow rate of 0.2 ml/min, with a run time of 12 min. Detection was on a triple quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. The acquisitions were in multiple reaction monitoring (MRM) mode using the following precursor-->product ion combinations: H-Tyr-His-OH (IS): m/z 319.2--> 156.5+301.6; GS-HNE: m/z 464.3--> 179.1+308.0; CAR-HNE: m/z 383.1--> 110.1+266.6; ANS-HNE: m/z 397.2--> 109.1+126.1. The method was validated over the concentration ranges 1.5-90 (GS-HNE) and 0.4-40 (CAR-HNE, ANS-HNE) nmoles/g wet tissue, and the LLOQ were 1.25 and 0.33 pmoles injected respectively. The intra- and inter-day precisions (CV%) were <7.38% (
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
4-Hydroxy-trans-2-nonenal; Anserine; Carnosine; Glutathione; Histidine-containing peptides; LC-ESI-MS/MS; Michael adducts; Oxidative stress markers; Rat skeletal muscle
Elenco autori:
M. Orioli, G. Aldini, G. Beretta, R. Maffei Facino, M. Carini
Link alla scheda completa: