Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Rapid determination of Sr-90 impurities in freshly generator eluted Y-90 for radiopharmaceutical preparation

Articolo
Data di Pubblicazione:
2009
Citazione:
Rapid determination of Sr-90 impurities in freshly generator eluted Y-90 for radiopharmaceutical preparation / M. Bonardi, L. Martano, F.M. Groppi Garlandini, M. Chinol. - In: APPLIED RADIATION AND ISOTOPES. - ISSN 0969-8043. - 67:10(2009 Oct), pp. 1874-1877. [10.1016/j.apradiso.2009.06.005]
Abstract:
Y-90 is one of the most useful radionuclides for radioimmunotherapeutic applications and has a half-life (t(1/2) = 64.14 h) suitable for most therapeutic applications, beta particles of high energy and decays to a stable daughter. it is significant that Y-90 is available conveniently and inexpensively from a radionuclide "generator" by decay of its parent, Sr-90. Nevertheless, current and planned clinical applications with [Y-90] labelled compounds employ activity levels that cannot be readily obtained from an in-house generator, but from commercial sources. We have evaluated Eichrom's Sr-resin, either as an "in-house" generator or as a fast QC method for analysis of Y-90 solutions. In particular, for the development as a generator, we investigated the percentage of the radio-Sr in the first 8 M HNO3 eluate: in this fraction the concentration of Sr-90 must be smaller than 10(-5)% (recommendations of the International Commission on Radiological Protection). For evaluation as a rapid QC method, we analyzed the concentration of Y-90 in all the fractions containing "only" radio-Sr: Y-90 should not be present in these eluates. After the collection of beta(-) and gamma spectra and analysis of them, we concluded that commercial Sr-resin minicolumn cannot give us the results expected; we developed an in-house system loaded with 4 mL of Sr-resin which gave better results as a generator and a rapid QC method.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Sr-90/Y-90 generator ; radiopharaceuticals ; quality assurance protocol ; Sr-90 contamination ; extraction method ; Y-90 for human use ; nuclear medicine
Elenco autori:
M. Bonardi, L. Martano, F.M. Groppi Garlandini, M. Chinol
Autori di Ateneo:
GROPPI GARLANDINI FLAVIA MARIA ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/152111
  • Aree Di Ricerca

Aree Di Ricerca

Settori (2)


Settore CHIM/03 - Chimica Generale e Inorganica

Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0