Occlusive Shrinkage of Ovation Endograft Presenting as Acute Lower Limb Ischemia : Effective Endovascular Management

Articolo
Data di Pubblicazione:
2017
Citazione:
Occlusive Shrinkage of Ovation Endograft Presenting as Acute Lower Limb Ischemia : Effective Endovascular Management / P. Bianchi, F. Scalise, A. Mortara, G. Lanzillo, G. Scardina, S. Trimarchi, G. Parati, V. Tolva. - In: AORTA. - ISSN 2325-4637. - 5:1(2017), pp. 21-26. [10.12945/j.aorta.2017.16.041]
Abstract:
The aim of this report is to describe the imaging and successful treatment of an acute shrinkage of the Ovation Abdominal Stent Graft System. The Ovation Prime system utilizes a polymer-filled sealing ring that is cast in situ at the margin of the aneurysm; however, the residual endograft inner volume after ring filling may reduce volume and graft flow. Nevertheless, there are no reports about severe complications using the Ovation Prime system. A 75-year-old male presented to our hospital for acute lower limb ischemia. The patient reported a previous endograft for abdominal aortic aneurysm 1 month previously, which utilized the Ovation device. Computed tomography (CT) angiography demonstrated a critical narrowing of the endograft at the site of the proximal sealing rings. We decided on urgent treatment, delivering a covered stent graft (CP STENT NUMED™). Intraoperative intravascular ultrasound showed effective compaction of the proximal rings. Nine-month follow-up with CT angiography demonstrated good patency without ring recoil of the endograft. This is the first report of endovascular treatment for an acute and symptomatic shrinkage of proximal rings in the Ovation trivascular endograft. Angiographic and intravascular ultrasound findings showed that covered stenting is effective and that the ring polymer is safely moldable.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Aortic sealing; EVAR; Endovascular complication
Elenco autori:
P. Bianchi, F. Scalise, A. Mortara, G. Lanzillo, G. Scardina, S. Trimarchi, G. Parati, V. Tolva
Autori di Ateneo:
TRIMARCHI SANTI ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/994337
Link al Full Text:
https://air.unimi.it/retrieve/handle/2434/994337/2269296/j.aorta.2017.16.041.pdf
  • Aree Di Ricerca

Aree Di Ricerca

Settori


Settore MED/22 - Chirurgia Vascolare
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.1.3.0