Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • People
  • Projects
  • Fields
  • Units
  • Outputs
  • Third Mission

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • People
  • Projects
  • Fields
  • Units
  • Outputs
  • Third Mission
  1. Outputs

Analysis of cardiac left-ventricular volume based on time warping averaging

Academic Article
Publication Date:
2002
Citation:
Analysis of cardiac left-ventricular volume based on time warping averaging / E.G. Caiani, A. Porta, G. Baselli, M. Turiel, S. Muzzupappa, M. Pagani, S. Cerutti. - In: MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING. - ISSN 0140-0118. - 40:2(2002), pp. 225-233.
abstract:
The cardiac left-ventricular (LV) volume signal, obtained by acoustic quantification, is affected by noise and respiratory modulation, resulting in a large beat-to-beat variability that affects the computation of LV function indices. A new method is proposed to improve the evaluation of LV indices by applying a signal averaging technique based on dynamic time warping to consecutive LV volume waveforms. Volume signals obtained from ten normal young (NY) subjects (mean age +/- SD: 25+/-5 years) were used to evaluate the performance of this algorithm. To evaluate its clinical utility, the effects of ageing and pharmacologically induced changes on LV function were assessed by studying, respectively, ten normal (N) adult subjects (age 64+/-8 years) and ten patients with dilated cardiomyopathy during a control and low-dose dobutamine (10 microg kg(-1) min(-1)) study. Indices of LV function were highly consistent, with a variability of less than 8%, even when only 16 beats were averaged, independently of their selection inside the whole recording. When compared with beat-to-beat measures, the averaging of 16 beats significantly reduced (by more than 50%) the interbeat variability of all indexes. Expected alterations in both diastolic and systolic function were evidenced both with ageing (peak filling atrial contraction and ejection rates: from 275+/-77 mls(-1), 76+/-30 ml s(-1) 230+/-70 mls(-1), respectively, in NY, to 160+/-33 mls(-1), 125+/-39 mls(-1), 163+/-54 mls(-1) in N) and with dobutamine (peak filling and ejection rates from 160+/-72 mls(-1) and 183+/-86 mls(-1) respectively, in control, to 253+/-75 mls(-1) and 251+/-105 mls(-1) with dobutamine). Signal averaging with time warping allows fast and improved assessment of LV function.
IRIS type:
01 - Articolo su periodico
List of contributors:
E.G. Caiani, A. Porta, G. Baselli, M. Turiel, S. Muzzupappa, M. Pagani, S. Cerutti
Authors of the University:
PORTA ALBERTO ( author )
Link to information sheet:
https://air.unimi.it/handle/2434/6312
  • Research Areas

Research Areas

Concepts (3)


Settore ING-INF/06 - Bioingegneria Elettronica e Informatica

Settore MED/09 - Medicina Interna

Settore MED/11 - Malattie dell'Apparato Cardiovascolare
  • Guide
  • Help
  • Accessibility
  • Privacy
  • Use of cookies
  • Legal notices

Powered by VIVO | Designed by Cineca | 26.7.0.0