New Fricke gel with high sensitivity and low diffusion for 3D-MRI dosimetry=Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI
Abstract
Data di Pubblicazione:
2018
Citazione:
New Fricke gel with high sensitivity and low diffusion for 3D-MRI dosimetry=Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI / C. Collura, S. Gallo, S. Nici, B. Abbate, L. Tranchina, S. Caracappa, G. Cassata, F. D’Errico, M. Marrale - In: Fisica Medica, un ponte tra presente e futuroPrima edizione. - [s.l] : AIFM, 2018 Apr 12. (( Intervento presentato al 10. convegno Congresso Nazionale AIFM tenutosi a Bari nel 2018.
Abstract:
Their effective atomic number and density are similar to those of soft tissue. In view of their chemical and morphological characteristics, FG serve as dosimeters and as phantoms at the same time. FG dosimeters are obtained by incorporating an acidic aqueous solution of ferrous ions Fe2+ into a gel matrix. In order to address the limitations of gels based on natural matrices, we have studied FG produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA). Materials and Methods: The proposed gel contains 10% w/v of PVA and GTA of 1%w/v. A common formulation agarose gel was also prepared and studied for comparison. PVA-GTA gel samples were irradiated using 6 MV x-ray clinical beams. The PVA-GTA FG can be read out with magnetic resonance imaging (1.5T clinical MRI scanner and 7T MRI preclinical scanner for small animals). Results and Conclusions: MRI was performed with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA-GTA gels were found to offer good linearity in the range of 0-15 Gy and a stable signal for several hours after irradiation. The sensitivity was about 40% higher compared to gels produced with agarose as gelling agent. The analysis showed that the diffusion process is much slower (more than five times) for PVA-GTA gels than for agarose ones. The dosimetric accuracy of the 3D gels was investigated by comparing their response to percentage depth dose and off-axis ratio measurements made with an ionization chamber in a water phantom.
Tipologia IRIS:
03 - Contributo in volume
Keywords:
NMR; MRI; Dosimetry; Fricke gel; PVA
Elenco autori:
C. Collura, S. Gallo, S. Nici, B. Abbate, L. Tranchina, S. Caracappa, G. Cassata, F. D’Errico, M. Marrale
Link alla scheda completa:
Link al Full Text:
Titolo del libro:
Fisica Medica, un ponte tra presente e futuro