Use of XenX™, the latest ureteric occlusion device with guide wire utility: results from a prospective multicentric comparative study / F. Sanguedolce, E. Montanari, M. Alvarez Maestro, N. Macchione, S. Hruby, A. Papatsoris, P. Kallidonis, L. Villa, P. Honeck, O. Traxer, F. Greco. - In: WORLD JOURNAL OF UROLOGY. - ISSN 0724-4983. - 34:11(2016), pp. 1583-1589. [10.1007/s00345-016-1806-6]
Abstract:
Purpose: This is a prospective multicentric comparative study evaluating the performance of XenX—a new dual-purpose device for the prevention of stone fragments migration during ureteroscopic lithotripsy (URS). Methods: Between March 2014 and January 2015, 41 patients undertaking URS + XenX were matched with 41 patients undergoing standard URS. Patients included had unilateral ureteric stone(s) of 0.5–1.5 cm in maximum size. Demographics, complication rates and surgical outcomes were recorded for comparison. A Likert-like 5-grade scoring system was used for surgeons’ evaluation of XenX properties. Cost analysis was performed by comparing weighted mean costs of the relevant procedures. Results: Patients’ characteristics between the two groups were comparable. Lasering time was longer for XenX group (13.59 vs. 5.17 min; p = 0.0001) whilst use of basket and need of JJ stent insertion was more frequent in control group (19.5 vs. 97.6 %; p = 0.0001 and 22 vs. 35 %; p = 0.001, respectively). Intra-operative SFR was significantly higher for XenX group (100 vs. 85.4 %; p = 0.0001), but not at 4-week follow-up, after ancillary procedures were needed in 17.1 % of the control group. Surgeons’ evaluations for XenX were suboptimal for “Ease of Basketing” (2/5) and “Advancement of double J stent” (3/5). The use of XenX increased costs of procedures, but spared the costs associated to ancillary procedures and stent removals. Conclusions: XenX confirmed to be a safe and effective device especially for the treatment of upper ureteric tract stones; moreover, XenX may reduce the risk for the need of auxiliary procedures and for the insertion of a JJ stent.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Endoscopic lithotripsy; New technology; Preventive retropulsion device; Ureteric stone
Elenco autori:
F. Sanguedolce, E. Montanari, M. Alvarez Maestro, N. Macchione, S. Hruby, A. Papatsoris, P. Kallidonis, L. Villa, P. Honeck, O. Traxer, F. Greco
Link alla scheda completa: