Effetto delle correzioni dei dati misurati da stazioni eddy covariance sulla stima dei flussi evapotraspirativi
Articolo
Data di Pubblicazione:
2012
Citazione:
Effetto delle correzioni dei dati misurati da stazioni eddy covariance sulla stima dei flussi evapotraspirativi / C. Corbari, D. Masseroni, M. Mancini. - In: ITALIAN JOURNAL OF AGROMETEOROLOGY. - ISSN 2038-5625. - 2012:1(2012), pp. 35-51.
Abstract:
Eddy covariance measurements have to be adjusted to correctly estimate the evapotranspiration fluxes. The main objective of this work is to analyze instrumental and physical corrections which are connected to an inappropriate sensors position or fluid (air) physical propriety. The data have been measured by two micrometeorological stations located at Landriano (PV) and Livraga (LO) in the Po Valley. The results show that the physical corrections are dominant in respect to instrumental corrections generating an energy balance improvements of about 20%.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
Eddy covariance stations; Energy balance closure; Footprint; Instrumental corrections; Physical corrections
Elenco autori:
C. Corbari, D. Masseroni, M. Mancini