Multicenter study of the CX8 HIV RNA Quantitative Assay- A new comparative reverse transcriptase-PCR wich targets pol genomic region of HIV 1 for the measurement of Type B non type B and group O HIV-1 RNA
Articolo
Data di Pubblicazione:
2002
Citazione:
Multicenter study of the CX8 HIV RNA Quantitative Assay- A new comparative reverse transcriptase-PCR wich targets pol genomic region of HIV 1 for the measurement of Type B non type B and group O HIV-1 RNA / H. Troonen, H. Grey, G. Michel, F. Barin, J. Izopet, H.W. Knechten, G. Fadda, M.R. Gismondo, A. Zanetti, E.C.J. Claas, E.J. van Rensburg, V. Soriano, J. Alcami, A. Sonnerborg, L. Perrin, J. Clarke. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - (2002).
Abstract:
Performance characteristics of the Abbott LCx HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor HIV-1 Monitor v1.5, the Bayer Quantiplex HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at approximately 50 copies/ml, and log10 0.133 at approximately 400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV seronegative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10NucliSens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.
Tipologia IRIS:
01 - Articolo su periodico
Elenco autori:
H. Troonen, H. Grey, G. Michel, F. Barin, J. Izopet, H.W. Knechten, G. Fadda, M.R. Gismondo, A. Zanetti, E.C.J. Claas, E.J. van Rensburg, V. Soriano, J. Alcami, A. Sonnerborg, L. Perrin, J. Clarke
Link alla scheda completa: