Skip to Main Content (Press Enter)

Logo UNIMI
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione

Expertise & Skills
Logo UNIMI

|

Expertise & Skills

unimi.it
  • ×
  • Home
  • Persone
  • Attività
  • Ambiti
  • Strutture
  • Pubblicazioni
  • Terza Missione
  1. Pubblicazioni

Development of a sensitive plasma lenvatinib quantification method and validation in thyroid cancer patients

Articolo
Data di Pubblicazione:
2026
Citazione:
Development of a sensitive plasma lenvatinib quantification method and validation in thyroid cancer patients / C. Colombo, R.O.. - In: JOURNAL OF THE ENDOCRINE SOCIETY. - ISSN 2472-1972. - 10:8(2026 Aug), pp. bvag154.1-bvag154.8. [10.1210/jendso/bvag154]
Abstract:
Context Lenvatinib (LEN) is effective in the treatment of radioactive iodine refractory differentiated thyroid cancer (DTC), though it is associated with frequent and potentially severe adverse events (AEs). The dose dependency of LEN-related toxicity remains unclear, since no data are available on this topic. Objective This study aimed to investigate the relationship between LEN dose and plasma concentrations in real-life patients by a novel and validated method for quantifying LEN in plasma samples. Design and setting A sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for LEN quantification in plasma was set up, with a wide analytical range (0.7-500 ng/mL). Consecutive plasma samples from 19 patients with radioactive iodine-refractory, metastatic DTC were analyzed. Results A positive correlation between the administered LEN dose and plasma concentrations was found, particularly in patients on low doses (<18 mg daily). Linear mixed-effects models (LMMs) demonstrated significant interindividual variability in plasma LEN concentrations, contributing to 17% to 28% of the total variance. This variability was more pronounced at higher doses (>= 18 mg), being more likely the consequence of LEN-related AEs than of a dose-dependent effect. Conclusion This is the first real-life evaluation of interindividual LEN pharmacokinetics variability in advanced DTC patients, obtained by means of the newly developed HPLC-MS/MS method. Our results suggest that the dose-response relationship of LEN in radioactive iodine-refractory DTC may be more complex than previously understood, with substantial interpatient variability and dose-dependent effects. Further studies are needed to determine the implications of our findings in the clinical management of these patients.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
envatinib; RAI-refractory; thyroid cancer; plasma quantification; HPLC-MS/MS; adverse events;
Elenco autori:
C. Colombo, R. Ottria, M. Trevisan, E. Carbone, C. Moneta, M. Lugaresi, S. Casati, S. Vanerio, D. Ceruti, M. Succi, V. Cirello, S. De Leo, L. Persani, P. Ciuffreda, L. Fugazzola
Autori di Ateneo:
CASATI SARA ( autore )
CIRELLO VALENTINA ( autore )
CIUFFREDA PIERANGELA ( autore )
COLOMBO CARLA ( autore )
FUGAZZOLA LAURA ( autore )
LUGARESI MARINA ( autore )
MONETA CLAUDIA ( autore )
OTTRIA ROBERTA ( autore )
PERSANI LUCA ( autore )
TREVISAN MATTEO ( autore )
Link alla scheda completa:
https://air.unimi.it/handle/2434/1262585
Link al Full Text:
https://air.unimi.it/retrieve/handle/2434/1262585/3376064/Jendocrin%20soc%202026.pdf
Progetto:
Pharmacogenitics of Lenvatinib in advanced thyroid cancer patients: correlation with adverse events and clinical outcome
  • Aree Di Ricerca

Aree Di Ricerca

Settori (3)


Settore BIOS-07/A - Biochimica

Settore BIOS-11/A - Farmacologia

Settore MEDS-08/A - Endocrinologia
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Progettato da Cineca | 26.7.0.0