Cardiac Magnetic Resonance for Prophylactic Implantable-Cardioverter Defibrillator Therapy in Ischemic Cardiomyopathy: The DERIVATE-ICM International Registry
Articolo
Data di Pubblicazione:
2023
Citazione:
Cardiac Magnetic Resonance for Prophylactic Implantable-Cardioverter Defibrillator Therapy in Ischemic Cardiomyopathy: The DERIVATE-ICM International Registry / G. Pontone, A.I. Guaricci, L. Fusini, A. Baggiano, M. Guglielmo, G. Muscogiuri, A. Volpe, R. Abete, G. Aquaro, A. Barison, J. Bogaert, G. Camastra, S. Carigi, N. Carrabba, G. Casavecchia, S. Censi, G. Cicala, C.N. De Cecco, M. De Lazzari, G. Di Giovine, M. Di Roma, M. Dobrovie, M. Focardi, N. Gaibazzi, A. Gismondi, M. Gravina, C. Lanzillo, M. Lombardi, V. Lorenzoni, J. Lozano-Torres, C. Martini, F. Marzo, A. Masi, R. Memeo, C. Moro, A. Nese, A. Palumbo, A.G. Pavon, P. Pedrotti, M.P. Marra, S. Pica, S. Pradella, C. Presicci, M.G. Rabbat, C. Raineri, J.F. Rodriguez-Palomares, S. Sbarbati, U.J. Schoepf, A. Squeri, N. Sverzellati, R. Symons, E. Tat, M. Timpani, G. Todiere, A. Valentini, A. Varga-Szemes, P. Masci, J. Schwitter. - In: JACC. CARDIOVASCULAR IMAGING. - ISSN 1936-878X. - (2023), pp. 1-14. [Epub ahead of print] [10.1016/j.jcmg.2023.03.015]
Abstract:
Background: Implantable cardioverter-defibrillator (ICD) therapy is the most effective prophylactic strategy against sudden cardiac death (SCD) in patients with ischemic cardiomyopathy (ICM) and left ventricle ejection fraction (LVEF) ≤35% as detected by transthoracic echocardiograpgy (TTE). This approach has been recently questioned because of the low rate of ICD interventions in patients who received implantation and the not-negligible percentage of patients who experienced SCD despite not fulfilling criteria for implantation. Objectives: The DERIVATE (CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy)-ICM registry (NCT03352648) is an international, multicenter, and multivendor study to assess the net reclassification improvement (NRI) for the indication of ICD implantation by the use of cardiac magnetic resonance (CMR) as compared to TTE in patients with ICM. Methods: A total of 861 patients with ICM (mean age 65 ± 11 years, 86% male) with chronic heart failure and TTE-LVEF <50% participated. Major adverse arrhythmic cardiac events (MAACE) were the primary endpoints. Results: During a median follow-up of 1,054 days, MAACE occurred in 88 (10.2%). Left ventricular end-diastolic volume index (HR: 1.007 [95% CI: 1.000-1.011]; P = 0.05), CMR-LVEF (HR: 0.972 [95% CI: 0.945-0.999]; P = 0.045) and late gadolinium enhancement (LGE) mass (HR: 1.010 [95% CI: 1.002-1.018]; P = 0.015) were independent predictors of MAACE. A multiparametric CMR weighted predictive derived score identifies subjects at high risk for MAACE compared with TTE-LVEF cutoff of 35% with a NRI of 31.7% (P = 0.007). Conclusions: The DERIVATE-ICM registry is a large multicenter registry showing the additional value of CMR to stratify the risk for MAACE in a large cohort of patients with ICM compared with standard of care.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
cardiac magnetic resonance; heart failure; implantable cardioverter-defibrillator; ischemic dilated cardiomyopathy; primary prevention;
Elenco autori:
G. Pontone, A.I. Guaricci, L. Fusini, A. Baggiano, M. Guglielmo, G. Muscogiuri, A. Volpe, R. Abete, G. Aquaro, A. Barison, J. Bogaert, G. Camastra, S. Carigi, N. Carrabba, G. Casavecchia, S. Censi, G. Cicala, C.N. De Cecco, M. De Lazzari, G. Di Giovine, M. Di Roma, M. Dobrovie, M. Focardi, N. Gaibazzi, A. Gismondi, M. Gravina, C. Lanzillo, M. Lombardi, V. Lorenzoni, J. Lozano-Torres, C. Martini, F. Marzo, A. Masi, R. Memeo, C. Moro, A. Nese, A. Palumbo, A.G. Pavon, P. Pedrotti, M.P. Marra, S. Pica, S. Pradella, C. Presicci, M.G. Rabbat, C. Raineri, J.F. Rodriguez-Palomares, S. Sbarbati, U.J. Schoepf, A. Squeri, N. Sverzellati, R. Symons, E. Tat, M. Timpani, G. Todiere, A. Valentini, A. Varga-Szemes, P. Masci, J. Schwitter