Evaluation of the weight loss of raw beef cuts vacuum-packaged with two different techniques
Articolo
Data di Pubblicazione:
2019
Citazione:
Evaluation of the weight loss of raw beef cuts vacuum-packaged with two different techniques / S. Stella, D. Garavaglia, G. Francini, V. Vigano, C. Bernardi, E. Tirloni. - In: ITALIAN JOURNAL OF FOOD SAFETY. - ISSN 2239-7132. - 8:4(2019 Dec 05), pp. 8111.184-8111.187. [10.4081/ijfs.2019.8111]
Abstract:
In the present study, 25 cuts of shank form adult cattle coming from the same slaughtering batch, were withdrawn just after manual sectioning/deboning, and each divided into two pieces (Prox and Dist) of approximately the same weight, that were vacuum packaged by using two different packaging systems: vacuum chamber machine with a bag material and a thermo-forming packaging machine with top and bottom webs named BAG and THF respectively. The packed cuts were stored at 2-3°C for 20 days. The drip loss was calculated at the end of the storage as the difference between drained weight and net. Internal muscle pH and pH of the exudate present in the package and microbiological analyses (by pooling the samples) were performed at T0 and at the end of the storage. The drip loss, was significantly lower with BAG packaging: this difference was evident after 20 days of storage (average ± STD BAG vs THF = 1.04±0.36% vs 1.71±0.42%; P<0.01). The values were, in general, low for both the packaging systems, never above 2%. Moreover, shrink bag packages are characterized by better overall pack appearance and less plastic weight per pack. Forming step reduce the thickness of ther-moforming material lowering the mechanical resistance and the barrier to oxygen, on the contrary after shrinking bag materials are thickened. The pH of muscles was stable, although a slight increase was evidenced after 20 (average ± STD BAG vs THF= 5.73±0.05 vs 5.78±0.09; P<0.01), due to the ageing of meat. The pH of the exudate was equal at T20 (average ± STD BAG vs THF = 5.34±0.20 vs 5.33±0.17). The drip loss didn’t influence the development of all the microflora; in particular LAB, that represented the main microbial population, showed a gradual increase from T0 (2.20±0.41 Log CFU/g) to T20 (average ± STD BAG vs THF= 4.76±0.29 Log CFU/g vs 4.75±0.0.15 Log CFU/g). No Enterobacteriaceae showed an increase, if compared to the initial counts, due to the prolonged storage and the gradual growth of ephemeral microorganisms, without differences among the two series (Enterobacteriaceae: T0=<1.7 Log CFU/g to T20 average ± STD BAG vs THF = 2.83±0.77 Log CFU/g vs 3.09±0.0.70 Log CFU/g). In conclusion, the use of the BAG system demonstrated to have an effect in reducing the drip loss of beef cuts during the refrigerated storage, with only slight influence on the other characteristics of raw meat.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
drip loss; microbiology; packaging; pH; raw beef
Elenco autori:
S. Stella, D. Garavaglia, G. Francini, V. Vigano, C. Bernardi, E. Tirloni
Link alla scheda completa:
Link al Full Text: