Exercise capacity and ventilation inhomogeneity in cystic fibrosis: A cross-sectional study
Articolo
Data di Pubblicazione:
2020
Citazione:
Exercise capacity and ventilation inhomogeneity in cystic fibrosis: A cross-sectional study / S. Gambazza, R. Guarise, F. Carta, F. Ambrogi, M. Mirabella, A. Brivio, C. Colombo. - In: PEDIATRIC PULMONOLOGY. - ISSN 8755-6863. - 55:2(2020 Feb 02), pp. 394-400. [10.1002/ppul.24525]
Abstract:
Background Lung clearance index (LCI2.5) is a marker of overall lung ventilation inhomogeneity and has proven to be able to detect early peripheral damage in subjects with cystic fibrosis (CF), with greater sensitivity than conventional spirometry. Combining its sensitivity with the output of an incremental exercise testing, we hypothesized that any sign of ventilation inhomogeneity in subjects without severe airflow obstruction and with a normal exercise tolerance could be relevant for the CF team, tracking early lung disease and potential exercise limiting factors. Methods Patients with CF in clinical stable conditions were recruited between 2015 and 2017. Available spirometry, nitrogen multiple-breath washout test and symptoms-limited exercise testing performed as parts of patients' annual routine evaluation were considered for this cross-sectional study. To describe the relationship between exercise intensity and ventilation inhomogeneity, a linear regression analysis was performed using backward elimination based on Akaike information criteria. Results Seventy-seven patients (38 females) were included. S-acin and LCI2.5 were significantly higher in patients with an overall reduced exercise tolerance. Peak work developed during exercise was associated with body mass index (b = 5.25; 95% confidence interval [CI] = 1.53-8.98), forced expiratory volume in 1 second (FEV1; b = 3.71; 95% CI = 1.96-5.46), Pseudomonas aeruginosa chronic infection (b = -8.84; 95% CI = -15.84 to -1.84) but not with LCI2.5. Conclusion Exercise capacity and airflow obstruction are associated in this Italian CF cohort. Considering the greater discriminatory power of LCI2.5 over FEV1 and peak work, the Godfrey protocol without gas analysis cannot provide detailed information about lung function or efficiency. However, this incremental protocol without gas exchange measures can still provide the CF team with information about exercise tolerance and disability.
Tipologia IRIS:
01 - Articolo su periodico
Keywords:
cystic fibrosis; exercise tolerance; lung clearance index; multiple breath washout; ventilation inhomogeneity; Adolescent; Adult; Cohort Studies; Cross-Sectional Studies; Cystic Fibrosis; Exercise; Exercise Test; Female; Forced Expiratory Volume; Humans; Lung; Male; Pseudomonas Infections; Respiration; Young Adult; Exercise Tolerance
Elenco autori:
S. Gambazza, R. Guarise, F. Carta, F. Ambrogi, M. Mirabella, A. Brivio, C. Colombo
Link alla scheda completa: