Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
Articolo
Data di Pubblicazione:
2016
Citazione:
Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope / M. Solbiati, G. Costantino, G. Casazza, F. Dipaola, A. Galli, R. Furlan, N. Montano, R. Sheldon. - In: COCHRANE DATABASE OF SYSTEMATIC REVIEWS. - ISSN 1469-493X. - 2016:4(2016), pp. CD011637.1-CD011637.38. [10.1002/14651858.CD011637.pub2]
Abstract:
Background
The most recent syncope guideline recommends that implantable loop recorders (ILRs) are implanted in the early phase of evaluation of people with recurrent syncope of uncertain origin in the absence of high-risk criteria, and in high-risk patients after a negative evaluation. Observational and case-control studies have shown that loop recorders lead to earlier diagnosis and reduce the rate of unexplained syncopes, justifying their use in clinical practice. However, only randomised clinical trials with an emphasis on a primary outcome of specific ILR-guided diagnosis and therapy, rather than simply electrocardiogram (ECG) diagnosis, might change clinical practice.
Objectives
To assess the incidence of mortality, quality of life, adverse events and costs of ILRs versus conventional diagnostic workup in people with unexplained syncope.
Search methods
We searched the Cochrane Central Register of Controlled Trials (CENTRAL, Issue 3, 2015), MEDLINE, EMBASE, ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) Search Portal in April 2015. No language restriction was applied.
Selection criteria
We included all randomised controlled trials of adult participants (i.e. >= 18 years old) with a diagnosis of unexplained syncope comparing ILR with standard diagnostic workup.
Data collection and analysis
Two independent review authors screened titles and abstracts of all potential studies we identified as a result of the literature search, extracted study characteristics and outcome data from included studies and assessed risk of bias for each study using the criteria outlined in the Cochrane Handbook for Systematic Reviews of Interventions. We contacted authors of trials for missing data. We analysed dichotomous data (all-cause mortality and aetiologic diagnosis) as risk ratios (RR) with 95% confidence intervals (CI). We used the Chi(2) test to assess statistical heterogeneity (with P < 0.1) and the I-2 statistic to measure heterogeneity among the trials. We created a 'Summary of findings' table using the five GRADE considerations (study limitations, consistency of effect, imprecision, indirectness and publication bias) to assess the quality of a body of evidence as it relates to the studies which contribute data to the meta-analyses for the prespecified outcomes.
Main results
We included four trials involving a total of 579 participants. With the limitation that only two studies reported data on mortality and none of them had considered death as a primary endpoint, the meta-analysis showed no evidence of a difference in the risk of long-term mortality between participants who received ILR and those who were managed conventionally at follow-up (RR 0.97, 95% CI 0.41 to 2.30; participants = 255; studies = 2; very low quality evidence) with no evidence of heterogeneity. No data on short term mortality were available. Two studies reported data on adverse events after ILR implant. Due to the lack of data on adverse events in one of the studies' arms, a formal meta-analysis was not performed for this outcome.
Data from two trials seemed to show no difference in quality of life, although this finding was not supported by a formal analysis due to the differences in both the scores used and the way the data were reported. Data from two studies seemed to show a trend towards a reduction in syncope relapses after diagnosis in participants implanted with ILR. Cost analyses from two studies showed higher overall mean costs in the ILR group, if the costs incurred by the ILR implant were counted. The mean cost per diagnosis and the mean cost per arrhythmic diagnosis were lower for participants randomised to ILR implant.
Participants who underwent ILR implan